Cobra® Rigid Vent 3 Exhaust Vent for Roof Ridge
Effective attic ventilation is critical for a long-lasting roof!
A properly balanced attic ventilation system will help to:
Cobra® Rigid Vent 3 exhaust
Homeowner’s Best Choice
*Under controlled laboratory conditions **See ltd. warranty for complete coverage and restrictions |
Professional’s Best Choice
|
Balanced Ventilation Requirements
Balanced ventilation requires an equal amount of intake ventilation and exhaust ventilation. GAF-Elk recommends, at a minimum, providing 1 square foot of Net Free Ventilation for every 300 square feet of attic floor space. Consult local building codes for specific ventilation requirements in your area.
- Calculate the total square footage of the attic floor area (round up to the next highest number). This number will determine the minimum total linear feet of Cobra® Rigid Vent 3 exhaust vent that is needed.
- Find the appropriate amount of Cobra® Rigid Vent 3 exhaust vent and minimum intake ventilation that corresponds to the total attic square footage.
|
Based on 1/300 Rule
|
||
|
Total
Attic Square Footage |
Recommended Length of Cobra® Rigid Vent 3 Exhaust Vent (Feet) |
Minimum Intake Ventilation (Net Free Area in Sq. In.) |
1600
|
22
|
396
|
1900
|
26
|
468
|
2200
|
30
|
540
|
2500
|
34
|
614
|
2800
|
38
|
684
|
3100
|
42
|
756
|
3400
|
46
|
828
|
Cobra® Rigid Vent 3 exhaust vent has 18.0 sq. in./linear ft. of net free ventilating area.
NOTE: Always have a balanced ventilation system. In no case should the amount of exhaust ventilation at the ridge exceed the amount of soffit ventilation.